Double-click the iSIGHT component icon
.
The iSIGHT Component Editor appears.
From the iSIGHT Component Editor, click Browse.
The Select Description File dialog box appears.
Select the description file that you want to use, and click Open.
Isight
creates an input file that records the description file that the iSIGHT
component runs once you configure the component. You can map the file
parameters from one component to another.
For more information about parameter mapping, see Mapping Parameters and File Parameters in the Isight User’s Guide.
If desired, click Edit to update the input file’s
parameter settings.
For more information about the settings, see Configuring the File Parameter Information.
From the iSIGHT Run Mode list, select the run
mode:
Option |
Description |
Single |
iSIGHT runs a single task evaluation.
iSIGHT retains the design variable values for the best design state and
determines which single run can be instructed to re-run. This option
is useful in the following cases:- Evaluating a single new design point
- Testing the task set-up for correctness and design feasibility
- Re-running the best design case of a prior iteration
|
Task Plan |
iSIGHT executes the Task Plan steps
(design exploration tools) one at a time and automatically performs iterations
until the best result is found. |
Optimization Plans |
iSIGHT iteratively executes
the task under the control of an optimization technique. |
Design of Experiments Plan |
iSIGHT executes the
task under the control of a new DOE study. |
For more information about these modes, see Working with Task Plans in the Isight User’s Guide.
Click OK to save your changes and to close the