ProductsAbaqus/Explicit TypeModel data LevelModel There are no parameters associated with this option.
Data lines to define the CONWEP charge properties- First line
Equivalent mass of TNT in any preferred mass unit.
Multiplication factor to convert from the preferred mass unit to kilograms. The default is 1.0.
- Second line (enter a blank line if the analysis uses SI units)
Multiplication factor to convert from the analysis length unit to meter.
Multiplication factor to convert from the analysis time unit to second.
Multiplication factor to convert from the analysis pressure unit to pascal (N/m2).
|