ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEProperty module
Optional parameters
- PORE FLUID
-
This parameter applies only to Abaqus/Standard analyses.
Include this parameter if the latent heat of the pore fluid in a porous medium is being defined.
Data lines to define a material's latent heat
- First line
Latent heat per unit mass. (Units of JM−1.)
Solidus temperature.
Liquidus temperature.
Repeat this data line as often as necessary to define phase changes in the material; one line per phase change. Latent heat values must be given in ascending order of temperature.