ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAELoad module
 
Optional parameters
  
 - AMPLITUDE
 
 -  
Set this parameter equal to the name of the amplitude curve that defines the
  magnitude of the distributed fluxes during the step (Amplitude Curves).
 
If this parameter is omitted for uniform flux types in an 
  Abaqus/Standard
  analysis, the reference magnitude is applied immediately at the beginning of
  the step or linearly over the step, depending on the value assigned to the AMPLITUDE parameter on the 
  STEP option (Defining an analysis).
  If this parameter is omitted in an 
  Abaqus/Explicit
  analysis, the reference magnitude is applied immediately at the beginning of
  the step.
 
For nonuniform flux type SNU (which is available only in 
  Abaqus/Standard),
  the flux magnitude is defined in user subroutine 
  DFLUX, and AMPLITUDE references are ignored.
  
  
 - OP
 
 -  
Set OP=MOD (default) for existing 
  DSFLUXs to remain, with this option modifying existing fluxes or
  defining additional fluxes.
 
Set OP=NEW if all existing 
  DSFLUXs applied to the model should be removed.
  
  
  

Data lines to define
a distributed surface flux
- First line
 
 
- 
Surface name.
  
 - 
Distributed flux type label S or SNU.
  
 - 
Reference flux magnitude (units
  JT−1L−2). This value is needed for uniform
  fluxes only. If it is given for nonuniform fluxes, it will be passed into user
  subroutine 
  DFLUX, where the actual flux magnitude is defined.
  
 
Repeat this data line as
often as necessary to define distributed fluxes for different
surfaces.